Maintenance Manual > Disassembly and Reassembly > Driving Parts > X-axis Motor Assy
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.3.1 X-axis Motor Assy
Procedures
1. Move the Y-Bar to the farthest position.
2. Raise the Table to the highest position and then remove it.
Refer to “6.3.3 Table” for removing method.
3. Remove the Key Panel Assy.
Refer to ” 6.1.2 Key Panel Assy “ for removing method.
4. Loosen the two fixing screws of the coupling of the worm gear
side.
5. Remove the four cap screws that fix the X Motor BKT.
To turn power off, be sure to turn the main power OFF.
X-axis Motor Assy
fixing screws of the coupling
Screws of X motor side is fixed with the Screw
adhesive , it cannot be removed.
cap screw x4