© 2011 MIMAKI ENGINEERING CO.,LTD. 6.2.1 R.2.0 P.2
6.2.1 Head Assy
1
2
3
4
5
6
7
8
4. Close the cap of the Air Bleeder Tube.
5. Push the syringe to discharge 30 cc of F-200 Cleaning Liquid
from the nozzles.
6. Remove the cap of the Air Bleeder Tube.
7. Set the syringe filled with air to the Filter, and then inject the
air.
Remaining F-200 Cleaning Liquid is discharged from the Air
Bleeder Tube.
8. After discharging all F-200 Cleaning Liquid, inject another 60
cc air. (The Cleaning Liquid is discharged from the Air Bleeder
Tube.)
9. Close the cap of the Air Bleeder Tube, and remove the Filter.
10. Perform Step 1 to 9 to the other nozzle row.
• Note: If needed, remove the “GEN Head Holder” before
working.
Head
Dumper Adapter
Waste liquid
close the cap
Drain cleaning
liqiud from
Nozle
Filter
0.45um 25mm
F-200 Clearning
liquid
F-200 Clearning
liquid
Check F-200 Cleaning Liquid squirts out of all
the nozzles.
Air
Dumper Adapter
Head
Waste liquid
Remove the
cap
Filter
0.45um 25mm
Waste liq-
uid
Never pull the piston of the syringe.
Foreign material may be sucked into the noz-
zle.
After washing, be sure to fill ink in 24 hours.
GEN Head Holder
Two screws
Maintenance Manual > Disassembly and Reassembly > Ink-related Parts > Head Assy
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0