Maintenance Manual > Disassembly and Reassembly > Ink-related Parts > Pump Head
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
6.2.3 Pump Head
Removing Procedure of Pump Head
1. Confirm the pump position to be replaced.
2. Remove the Nut and Sleeve from each of the right and left
tubes.
3. Remove the Pump head.
(1) Remove the Pump base.
Screw x4
(2) Remove the Pump head from the Pump base.
To turn power off, be sure to turn the main power OFF.
Be sure to wear Protective Glasses and Working Gloves during the work operation.
Ink may get in your eyes depending on the working condition, or hand skin may get rough if you
touch the ink.
Wipe the blue cover of Pump Head with a dry cloth for cleaning.
Never use any chemicals such as alcohol, remover or the like since it may result in cracks or surface
separations of cover.
Be sure to start the work after confirming the working process.
(Refer to “3.1.3 Replacement of Pump Head”)
Take care not soil the surroundings.
The pump No. is identical with the Head No.
Take care not to confuse it.
Perform the following process with the removed
Station Assy upside down.
Take care not to stain any object by ink dripping.