© 2011 MIMAKI ENGINEERING CO.,LTD. 6.5.2 R.2.0 P.1
1
2
3
4
5
6
7
8
Maintenance Manual > Disassembly and Reassembly > Sensors > Z origin sensor
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
6.5.2 Z origin sensor
Working Procedure
1. Remove the Table.
• Refer to 6.3.3 Table.
2. Turn the main power off.
3. Remove the Z-Motor-Reinforce Plate.
4. Take the Sensor off.
• Remove fixing screw.
• Disconnect the connector of the sensor.
5. Perform the assembly by reversing the disassembly procedure.
To turn power off, be sure to turn the main power OFF.