Maintenance Manual > Disassembly and Reassembly > Sensors > Z origin sensor
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.5.2 Z origin sensor
Working Procedure
1. Remove the Table.
Refer to 6.3.3 Table.
2. Turn the main power off.
3. Remove the Z-Motor-Reinforce Plate.
4. Take the Sensor off.
Remove fixing screw.
Disconnect the connector of the sensor.
5. Perform the assembly by reversing the disassembly procedure.
To turn power off, be sure to turn the main power OFF.
Z origin sensor
Z-Motor-Reinforce Plate