7.1.2 P.9
7.1.2 List of Error Messages
1
2
3
4
5
6
7
8
Details of ERROR 12e Head Failed [xxxx]
The relationships between [xxxx] (hexadecimal numeral) bit No. and the error contents are as below:
66
ERROR 04
PARAM ROM
Access Error of the PARAMETER ROM
1.
The state that cannot access “ROM”
on the SL-Relay PCB.
2.
The state that cannot access
“EEPROM” on the HEAD2.
(If “PCB SLRY” is displayed for a few seconds while a
version is displayed at startup before displaying errors)
1. Disconnect and connect the FFC located between the
SL-Relay PCB and the Main PCB.
2. Disconnect and connect the FFC located between the
Slider PCB and the SL-Relay PCB.
3. Replace the FFC located between the SL-Relay PCB
and the Main PCB.
4.
Replace the FFC located between the Slider PCB and
the SL-Relay PCB.
5.
Replace the SL-Relay PCB.
6.
Replace the Slider PCB.
7.
Replace the Main PCB.
( If "Area:_H__" is displayed on the second line without
"PCB SLRY" displayed at startup by pressing [FUNC]
key while an error is displayed.)
1.
Disconnect and connect the FFC of the HEAD2.
2.
Replace the Slider PCB.
3.
Replace the HEAD2.
bit Hexadecimal
numeral indi-
cation
Reason for error occurrence Cause for occurrence
bit0 [0001]
Abnormal detection status of head signal (MN signal)
(Slider PCB)
1. Failure of head
2. Failure of Slider PCB
bit1 [0002]
COM-OFF signal output status
(Slider PCB)
1. FFC breakage between SL-Relay PCB and
Slider PCB
2. Failure of head
3. Failure of Slider PCB
bit2 [0004]
35V-1 Power supply voltage drop detection
(Slider PCB)
1. FFC breakage between SL-Relay PCB and
Slider PCB
2. Failure of Slider PCB
3. Failure of SL-Relay PCB
bit3 [0008]
Driving wave shape circuit Current limit over
(SL-Relay PCB)
1. Failure of SL-Relay PCB
(F2 blowout, COM circuit failure, etc.)
2. Failure of Slider PCB
3. Failure of head
However, when bit6 or bit7 is “1” and an error
([3F88] or [3FC8] etc.) has occurred at startup,
that error cause has priority.
bit4 [0010]
COM-OFF signal input status
(SL-Relay PCB)
1. FFC breakage between SL-Relay PCB and
Slider PCB
2. Failure of head
3. Failure of Slider PCB
bit5
Not Use
bit6 [0040]
37V of SL-Relay PCB is not normal.
(Displayed only at startup.)
1. Failure of SL-Relay PCB
List of Error Messages (9/9)
No. LCD Cause List of Countermeasures
R.2.0
Maintenance Manual > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages