CALL BACK
CALL BACK-DON’T ANSWER
CALL BACK-D
term
– 80 –
A2076-10
CALL BACK
CALL BACK-DON’T ANSWER
CALL BACK-D
term
PROGRAMMING
DESCRIPTION DATA
Provide the system with the Single Digit
Feature Access Code while calling the sta-
tion hears ringback tone/busy tone.
(1)
(2)
156: Ringback Tone
0: Available
(1)
(2)
208: Busy Tone
0: Available
To activate the Single Digit Feature Ac-
cess Code, set the data for CM08>050,
051, 069 and 148 to “1”.
(1)
(2)
050: * Button as Switch Hook Flash
1 : Ineffective
(1)
(2)
051: # Button as Switch Hook Flash
1 : Ineffective
(1)
(2)
069: Single Digit Dialing on BT Con-
nection
1 : Step Call
(1)
(2)
148: Same Last Digit Redialing on BT
Connection
1 : Ineffective
NOTE 1: A single digit access code “2” is fixedly assigned to this feature.
NOTE 2: While the calling D
term
, DP or DTMF telephone is holding the other call, the single
digit access code “2” is not available.
NOTE 3: From a DTMF telephone a hooking operation is required before dialing the single
digit access code.
Assign Service Restriction Class A to the
necessary stations.
•
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
START
CM08
CM12
A