EasyManua.ls Logo

NEC NEAX 2000 - DUAL HOLD-D Term

NEC NEAX 2000
1200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DUAL HOLD-D
term
– 247 –
A2247-10
DUAL HOLD-D
term
PROGRAMMING
HARDWARE REQUIRED
D
term
and DLC card
DESCRIPTION DATA
Assign the Service Restriction Class B for
this feature to required stations.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
ZZ: 00-15 : Service Restriction Class
B
Allow Dual Hold in the Service Restriction
Class B assigned by CM12 Y=02.
(1)
(2)
Y=64
00-15: Service Restriction Class B as-
signed by CM12 Y=02
1 : Allow
CM15
START
END
CM12

Table of Contents

Other manuals for NEC NEAX 2000

Related product manuals