ATTENDANT CONSOLE LOCKOUT-PASSWORD
– 34 –
A2032-10
ATTENDANT CONSOLE LOCKOUT-PASSWORD
PROGRAMMING
DESCRIPTION DATA
Assign the Mode key for providing Atten-
dant Console Lockout on the ATTCON.
(1)
(2)
Y=00
ATTCON No. (E000-E007) + + Key
No.
F6110
Assign the access code for providing At-
tendant Console Lockout for an ATTCON,
if required.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A155
Specify the buzzer sound when terminat-
ing an incoming call to the ATTCON in At-
tendant Console Lockout.
(1)
(2)
353
0 : Not provided
1 : To provide
Assign the password code for Attendant
Console Lockout.
(1)
(2)
Y=30
0
XX-XX: Password Code (Max. 8 digits)
X : 0-9, A (*) B (#)
If no data is set, the default setting is
NONE. In this case, the password is set to
“12345678”.
CM20
CM08
CM60
START
END
CM90
,