CALL FORWARDING-BUSY LINE
CALL FORWARDING-BUSY LINE-D
term
CALL FORWARDING-BUSY LINE-OUTSIDE
– 85 –
A2076-10
CALL FORWARDING-BUSY LINE
CALL FORWARDING-BUSY LINE-D
term
CALL FORWARDING-BUSY LINE-OUTSIDE
PROGRAMMING
DESCRIPTION DATA
Assign the Service Restriction Class A for
this feature to the required stations.
(1)
(2)
Y=02
X-XXXXXXXX: My Line No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
Allow Call Forwarding-Busy Line in the
Service Restriction Class A assigned by
CM12 Y=02.
NOTE: When providing Call Forwarding-
Busy Line-Outside, set “1” (Al-
low) for CM15 Y=11, Y=28, Y=12,
Y=29.
(1)
(2)
Y=11 Call Forwarding-Busy Line
Y=28 Call Forwarding-Busy Line-Out-
side
Y=12 Call Forwarding-Busy Line/-Don’t
Answer
Y=29 Call Forwarding- Busy Line-Out-
side/-Don’t Answer-Outside
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Assign the access code for Call Forward-
ing-Busy Line.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A014: Set
A015: Cancel
For setting the same access code as Call
Forwarding-Don’t Answer
(2) A012: Set
A013: Cancel
CM15
CM20
START
CM12
A

Table of Contents

Other manuals for NEC NEAX 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC NEAX 2000 and is the answer not in the manual?

NEC NEAX 2000 Specifications

General IconGeneral
BrandNEC
ModelNEAX 2000
CategoryServer
LanguageEnglish

Related product manuals