PERIODIC TIME INDICATION TONE
– 383 –
A2382-10
PERIODIC TIME INDICATION TONE
PROGRAMMING
DESCRIPTION DATA
Provide the system with this feature.
And, specify availability of this service on
Tie Line call.
(1)
(2)
135: On outgoing C.O. line call
0: To provide
(1)
(2)
136: On outgoing Tie line call
0 : To provide
1 : Not provided
Assign the Service Restriction Class B for
this feature to required stations.
•
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
ZZ: 00-15 : Service Restriction Class
B
Allow Periodic Time Indication Tone in the
Service Restriction Class B assigned by
CM12 Y=02.
•
(1)
(2)
Y=61
00-15: Service Restriction Class B as-
signed by CM12 Y=02
1 : Allow
Assign required stations as Ordinary Sta-
tion.
If assigned to 0 (Analog Data Station), this
feature will not be applied to the station.
•
(1)
(2)
Y=07
X-XXXXXXXX: Station No.
1 : Ordinary Station
Specify the timing interval for Periodic
Time Indication Tone.
•
(1)
(2)
Y=0
09
00-12: 36 sec.-724 sec.
(28 sec. (01)/60 sec. (02-12) incre-
ments)
If no data is set, the default setting is 180-
184 sec.
START
END
CM08
CM13
CM41
CM12
CM15