HOUSE PHONE
– 273 –
A2270-10
HOUSE PHONE
PROGRAMMING
DESCRIPTION DATA
Assign House Phone Group number to re-
quired stations.
NOTE: There is no limit to the number of
House Phone permitted in the
system as long as the maximum
number of ports is not exceeded.
(1)
(2)
Y=03
X-XXXXXXXX: Station No.
00-03: House Phone Group 0-3
Assign the destination of each House
Phone Group.
(1)
(2)
Y=14
00-03: House Phone Group 0-3
X-XXXXXXXX: Station No. of the desti-
nation
E000: Attendant Console
For assigning the Attendant Console as
destination, set “E000” to each House
Phone Group.
Specify the result of Switch Hook Flash on
stations within each House Phone Group.
To allow stations within a House Phone
Group to transfer a call or access a fea-
ture, set the data to “0”.
(1)
(2)
055: For House Phone Group 0, 1
056: For House Phone Group 2, 3
0 : Special Dial Tone
1 : Attendant Recall
CM51
CM08
START
END
CM12