OVERFLOW ANNOUNCEMENT-UCD
– 366 –
A2356-10
OVERFLOW ANNOUNCEMENT-UCD
PROGRAMMING
DESCRIPTION DATA
Assign the incoming call to queuing mode
when all UCD stations are busy.
(1)
(2)
212
1 : Queuing
Assign the DAT card to the required LEN.
NOTE: The DAT card number must be
assigned to the first LEN (Level
0), the third LEN (Level 2), the
fifth LEN (Level 4) and the sev-
enth LEN (Level 6) of each LT
slot.
(1)
(2)
000-763: LEN
EB002-EB127: DAT Card No.
For PIM0/1: EB002-EB031
For PIM2/3: EB032-EB063
For PIM4/5: EB064-EB095
For PIM6/7: EB096-EB127
NOTE: EB000 and EB001 are dedi-
cated to built-in Digital An-
nouncement Trunk of the MP
card.
Designate the number of queuing in each
UCD group.
(1)
(2)
Y=B
X-XXXXXXXX: Pilot station No. of the
UCD group
0 : To provide (See CM42>16)
1 : Not provided
Specify the maximum number of queuing
in each UCD group.
(1)
(2)
16
01-99: Number of queuing in each UCD
group
If no data is set, the default setting is no lim-
it.
Specify the message duration of UCD
Overflow Announcement.
(1)
(2)
Y=0
66
01-99: 4 sec.-396 sec.
(4 sec. increments)
If no data is set, the default setting is 60-64
sec.
Assign the function of UCD Overflow An-
nouncement to the DAT card.
(1)
(2)
Y=00
000-001: Built-in DAT on MP card
002-127: DAT Card (EB002-EB127)
No. assigned by CM10
12XX
XX: 00-15: UCD Group No.
CM10
CM17
CM42
START
CM08
CM41
CM49
END