AUTOMATIC RECALL
AUTOMATIC RECALL-D
term
– 68 –
A2066-10
AUTOMATIC RECALL
AUTOMATIC RECALL-D
term
PROGRAMMING
DESCRIPTION DATA
Specify the timing for AUTOMATIC RE-
CALL.
If no data is set, the following timing will be
applied:
Attendant Recall : 31.2-33.6 sec.
Non Exclusive Hold: 60-64 sec.
Exclusive Hold : 236-240 sec.
Transfer Recall : 24-28 sec.
Camp-On Recall : 24-32 sec.
•
(1)
(2)
Y=0
00: Attendant Recall
01-14: 2.4 sec.-33.6 sec.
(2.4 sec. increments)
15-24: 38.4 sec.-124.8 sec.
(9.6 sec. increments)
If no data is set, the default setting is 31.2-
33.6 sec.
(1)
(2)
05: Non Exclusive Hold
01-98: 4 sec.-392 sec.
(4 sec. increments)
99 : Recall is not performed
If no data is set, the default setting is 60-64
sec.
(1)
(2)
06: Exclusive Hold
01-98: 4 sec.-392 sec.
(4 sec. increments)
99 : Recall is not performed
If no data is set, the default setting is 236-
240 sec.
(1)
(2)
07: Transfer Recall
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 24-28
sec.
CM41
START
A