TANDEM SWITCHING OF TIE TRUNKS-2/4-WIRE
– 503 –
A2499-10
TANDEM SWITCHING OF TIE TRUNKS-2/4-WIRE
PROGRAMMING
HARDWARE REQUIRED
LDT/ODT card
DESCRIPTION DATA
Specify the combination of Trunk Routes
allowing the Tandem connection.
Incoming Trunk Route must provide re-
lease signal for Tandem Connection. (See
CM35 Y=05)
•
(1)
(2)
Y=0
XX ZZ
XX: 00-63: Incoming Trunk Route
ZZ: 00-63: Outgoing Trunk Route
0 : Allow
1 : Restricted
CM36
START
END