TIMED REMINDER
– 516 –
A2512-10
TIMED REMINDER
PROGRAMMING
To provide the internal music source on the MP card:
DESCRIPTION DATA
Assign the Service Restriction Class A for
Timed Reminder to required stations.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
Allow Timed Reminder in the Service Re-
striction Class A assigned by CM12 Y=02.
(1)
(2)
Y=13
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Assign the access code for Timed Re-
minder set and cancel.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A024: Set
A025: Cancel
Designate the type of tone source to be
connected when answering a Timed Re-
minder call.
(1)
(2)
Y=1
00: Tone source of Timed Reminder
1400: Hold Tone source on MP card
Assign the Timed Reminder feature ac-
cess key to a D
term
, if required.
(1)
(2)
Y=00
My Line No. + + Key No.
F0024
Specify the timing for Timed Reminder
Start.
(1)
(2)
228: Timed Reminder Start timing
0 : At preset time
1 : Before 5 minutes of preset time
Specify the duration of a Timed Reminder
call.
(1)
(2)
Y=0
23
01-08: 4 sec.-32 sec.
(4 sec. increments)
If no data is set, the default setting is 28-32
sec.
CM15
CM20
CM48
START
CM12
CM90
CM08
CM41
A
INITIAL
,