EasyManuals Logo

NEC NEAX 2000 Programming Manual

NEC NEAX 2000
1200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #306 background imageLoading...
Page #306 background image
LEAST COST ROUTING-3/6 DIGIT
– 286 –
A2286-10
LEAST COST ROUTING-3/6 DIGIT
PROGRAMMING
DESCRIPTION DATA
Assign the access code for LCR Group 0-
2.
(1)
(2)
Y=0-3 Number Plan Group 0-3
X-XXXX: Access Code
A126: LCR Group 0
A127: LCR Group 1
A128: LCR Group 2
Assign the Toll Restriction Patterns with
eight kinds of Trunk Restriction Classes
assigned by CM12 Y=01.
Toll Restriction Pattern 00-15 are preas-
signed as shown below.
If a new Restriction Pattern is required,
change the data for Restriction Pattern 01-
13 (00, 14 and 15 are fixed).
(1)
(2)
Y=01-13
Toll Restriction Pattern No. 01-13
1-8: Trunk Restriction Class
0: Restricted
3: Allowed
CM81
START
CM20
A
0: Restricted
3: Allowed
TRUNK
RESTRICTION
CLASS
Y
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
1 RCA 3 0 3 3 3 0 0 0 3 3 3 3 3 0 3 0
2 RCB 3 0 3 3 0 0 0 0 3 3 0 0 0 0 3 0
3 RCC 3 0 3 0 0 0 0 0 3 0 0 0 0 0 3 0
4 RCD 3 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0
5 RCE 3 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0
6 RCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0
7 RCG 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0
8 RCH 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0

Table of Contents

Other manuals for NEC NEAX 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC NEAX 2000 and is the answer not in the manual?

NEC NEAX 2000 Specifications

General IconGeneral
BrandNEC
ModelNEAX 2000
CategoryServer
LanguageEnglish

Related product manuals