LEAST COST ROUTING-3/6 DIGIT
– 286 –
A2286-10
LEAST COST ROUTING-3/6 DIGIT
PROGRAMMING
DESCRIPTION DATA
Assign the access code for LCR Group 0-
2.
(1)
(2)
Y=0-3 Number Plan Group 0-3
X-XXXX: Access Code
A126: LCR Group 0
A127: LCR Group 1
A128: LCR Group 2
Assign the Toll Restriction Patterns with
eight kinds of Trunk Restriction Classes
assigned by CM12 Y=01.
Toll Restriction Pattern 00-15 are preas-
signed as shown below.
If a new Restriction Pattern is required,
change the data for Restriction Pattern 01-
13 (00, 14 and 15 are fixed).
(1)
(2)
Y=01-13
Toll Restriction Pattern No. 01-13
1-8: Trunk Restriction Class
0: Restricted
3: Allowed
CM81
START
CM20
A
0: Restricted
3: Allowed
TRUNK
RESTRICTION
CLASS
Y
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
1 RCA 3 0 3 3 3 0 0 0 3 3 3 3 3 0 3 0
2 RCB 3 0 3 3 0 0 0 0 3 3 0 0 0 0 3 0
3 RCC 3 0 3 0 0 0 0 0 3 0 0 0 0 0 3 0
4 RCD 3 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0
5 RCE 3 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0
6 RCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0
7 RCG 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0
8 RCH 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0