TOLL RESTRICTION-3/6-DIGIT
– 527 –
A2523-10
TOLL RESTRICTION-3/6-DIGIT
PROGRAMMING
DESCRIPTION DATA
Provide the system with the Toll Restric-
tion feature for an outgoing call by Speed/
Calling-Station/System, if desired.
(1)
(2)
035: Speed Calling-System
0 : Not provided
1 : To provide
(1)
(2)
044: Speed Calling-System
0 : Not provided
1 : To provide
Assign a Trunk Restriction Class to each
station.
•
(1)
(2)
Y=01
X-XXXXXXXX: Station No.
X Z: Trunk Restriction Class
X: 1-8: In Day Mode
Z: 1-8: In Night Mode
1 : Unrestricted (RCA)
2 : Non-Restricted 1 (RCB)
3 : Non-Restricted 2 (RCC)
4 : Semi-Restricted 1 (RCD)
5 : Semi-Restricted 2 (RCE)
6 : Restricted 1 (RCF)
7 : Restricted 2 (RCG)
8 : Fully-Restricted (RCH)
Assign the data for Dial Pulse sending to
the Route number assigned.
•
(1)
(2)
Y=08 Dial Pulse Sending
00-63: Trunk Route No.
3 : To send
Provide the Toll Restriction feature to re-
quired trunk routes.
•
(1)
(2)
Y=11
00-63: Trunk Route No.
0: To provide
Specify outgoing route access capability
for each restriction class.
•
(1)
(2)
Y=51-58
00-63: Trunk Route No.
0 : Restricted
1 : Allowed
Assign the Area Code Development Pat-
tern number for Toll Restriction and maxi-
mum digit analysis to each trunk route.
•
(1)
(2)
Y=76
00-63: Trunk Route No.
00-04: Area Code Development Pat-
tern No. 0-4
CM12
START
CM08
CM35
A