AUTOMATIC CHANGE OF NIGHT SERVICE
– 63 –
A2056-10
AUTOMATIC CHANGE OF NIGHT SERVICE
PROGRAMMING
NOTE: Refer to “AUTOMATED ATTENDANT”
page 56
when using the Automated At-
tendant as the destination of Automatic Change of Night Service.
DESCRIPTION DATA
Provide the system with Automatic
Change of Night Service.
(1)
(2)
067
0: Available
Assign the data for terminating system in
Day Mode and Night Mode for each trunk.
(1)
(2)
Y=02 Day Mode
000-255: Trunk No.
14: Termination to Attendant Console
(1)
(2)
Y=03 Night Mode
000-255: Trunk No.
04: Direct-In Termination
09: Automated Attendant
Note
(1)
(2)
Y=05 Night Station Assignment
000-255: Trunk No.
X-XXXXXXXX: Night Station No.
Specify the timing for Automatic Change of
Night Service.
(1)
(2)
Y=0
01
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
CM30
CM41
START
CM08
END