TRUNK TO TRUNK CONNECTION
– 540 –
A2536-10
TRUNK TO TRUNK CONNECTION
PROGRAMMING
DESCRIPTION DATA
Assign the Service Restriction Class C to
each station.
•
(1)
(2)
Y=07
X-XXXXXXXX: My Line No.
00-15 : Service Restriction Class C
Provide the switch hook flash capability
during C.O. line connection in the Service
Restriction Class C assigned by CM12
Y=07.
•
(1)
(2)
Y=90, 91
00-15: Service Restriction Class C as-
signed by CM12 Y=07
1 : Allow
Specify the combination of trunk routes al-
lowing the Trunk to Trunk Connection.
•
(1)
(2)
Y=0
XX ZZ
XX: 00-63: Incoming trunk route
ZZ: 00-63: Outgoing trunk route
0 : Allow
1 : Restricted
Provide the system with Ring Transfer for
Call Transfer-All Calls to a trunk when a
station holds another station or trunk.
(1)
(2)
253
0: Available
Provide the system with forced release
when a tandem call duration passes a pre-
determined time.
(1)
(2)
029
0 : To disconnect
1 : To continue
Allow or restrict forced release of tandem
connection for the incoming trunk route.
This data is available when CM08>029 is
set to 0.
•
(1)
(2)
Y=119
00-63: Trunk Route No.
0 : Allow
1 : Restricted
Specify the forced release timing for tan-
dem call.
•
(1)
(2)
Y=0
54
01-06: 64 min.-224 min.
(32 min. increments)
If no data is set, the default setting is 96-128
min.
CM15
CM08
CM35
START
CM12
CM41
CM36
A

Table of Contents

Other manuals for NEC NEAX 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC NEAX 2000 and is the answer not in the manual?

NEC NEAX 2000 Specifications

General IconGeneral
BrandNEC
ModelNEAX 2000
CategoryServer
LanguageEnglish

Related product manuals