PAD LOCK
– 369 –
A2369-10
PAD LOCK
PROGRAMMING
To provide Pad Look feature, Authorization Code and Maid Status Code assignment is used.
There are two kinds of processor for Authorization Code.
One is MP card, the other is AP01 card.
For MP card, EXPMEM card can be used to expand the number of codes.
(1) With AP01 card:
DESCRIPTION DATA
Assign the AP number to AP01 card.
The AP number must match the SENSE
switch on the AP01 card.
(1)
(2)
Y=0
04-15: AP No.
07: AP01 card
Designate the AP01 card for Authorization
Code.
(1)
(2)
216: Designation of Processor for Au-
thorization Code
1 : AP01 card
Specify the Service Set Tone after dialing
the access code for Authorization Code.
(1)
(2)
362: Service Set Tone after dialing the
access code
1 : Service Set Tone
Set the data for 281 to 1. (Maid ID Code is
not used.)
(1)
(2)
281
1 : Not available
Assign the Service Restriction Class A al-
lowed for Authorization Code feature.
(1)
(2)
Y=31 Authorization Code
00-15: Service Restriction Class A
1 : Allow
Assign allowed class and restricted class
for Maid Status feature in the Service Re-
striction Class B.
(1)
(2)
Y=75 Maid Status
00-15: Service Restriction Class B
0 : Restricted
1 : Allow
CM08
CM15
START
CM05
A
INITIAL

Table of Contents