RING FREQUENCY CONTROL-D
term
– 416 –
A2412-10
RING FREQUENCY CONTROL-D
term
PROGRAMMING
To control the ring frequency by system data programming:
DESCRIPTION DATA
Enable the frequency control by system
data programming.
(1)
(2)
390
1 : As per CM15 Y=83, 84, CM35
Y=34
Specify the ring frequency of each D
term
for internal calls.
(1)
(2)
Y=07
X-XXXXXXXX: Station No.
00-15 : Service Restriction Class C
(1)
(2)
Y=83, 84
00-15: Service Restriction Class C
assigned by CM12 Y=07
0 : See left column.
1 : See left column.
Specify the ring frequency for incoming
calls to each trunk route.
(1)
(2)
Y=34
00-63: Trunk Route No.
0 : 1024 + 1285 [Hz]
× 16 [Hz]
1 : 480 + 606 [Hz]
× 8 [Hz]
2 : 600 + 700 [Hz]
3 : 480 + 606 [Hz]
× 16 [Hz]
START
END
CM08
CM15
CM12
CM35
INITIAL
Y
RING FREQUENCY
83 84
0 0 600 + 700 [Hz]
1 0 1024 + 1285 [Hz] × 16 [Hz]
0 1 480 + 606 [Hz] × 8 [Hz]
1 1 480 + 606 [Hz] × 16 [Hz]