INTERNAL ZONE PAGING-D
term
– 283 –
A2280-10
INTERNAL ZONE PAGING-D
term
PROGRAMMING
To provide Internal Zone Paging within a single assigned zone:
DESCRIPTION DATA
Assign the Service Restriction Class A for
Internal Zone Paging to the required sta-
tions.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
Allow Internal Zone Paging in the Service
Restriction Class A assigned by CM12
Y=02.
(1)
(2)
Y=49
00-15: Service Restriction Class A
assigned by CM12 Y=02
1 : Allow
Assign Internal Zone Paging access
codes and Meet-Me answer codes, as
required.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access code
A130-A137: Paging Access Group 0-7
A138-A145: Meet-Me Answer Group
0-7
Assign the D
term
s into the Internal Zone
Paging Groups.
NOTE: A maximum of 8 internal zone
paging is available. Up to 16
D
term
s can be grouped per zone.
(1)
(2)
Y=00-07 Paging Group No.
00-15: Serial No. in a Paging Group
X-XXXXXXXX: My Line No.
Assign Internal Zone Paging to each but-
ton on the D
term
.
(1)
(2)
Y=00
My Line No. + + Key No.
F1270-F1277: Internal Zone Paging
Group 0-7
CM20
CM56
CM90
START
END
CM15