INTERNAL ZONE PAGING-D
term
– 284 –
A2280-10
To provide Internal Zone Paging within a maximum of six zones simultaneously (All Zone Internal
Paging):
HARDWARE REQUIRED
D
term
and DLC card
DESCRIPTION DATA
Provide the system with All Zone Internal
Paging.
(1)
(2)
158
1 : Available
Assign the Service Restriction Class A for
All Zone Internal Paging to the required
stations.
•
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
Allow Internal Zone Paging in the Service
Restriction Class A assigned by CM12
Y=02.
•
(1)
(2)
Y=49
00-15: Service Restriction Class A
assigned by CM12 Y=02
1 : Allow
Assign an All Zone Internal Paging access
code, as required.
•
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access code
A164: All Zone Internal Paging Access
Assign Group for Internal Zone Paging to
the required D
term
s.
NOTE: A maximum of 6 zones (0-5) in-
ternal paging groups are avail-
able. Up to 16 D
term
s can be
grouped per zone.
•
(1)
(2)
Y=00-05 Paging Group No.
00-15: Serial No. in a Paging Group
X-XXXXXXXX: My Line No.
Assign an All Zone Internal Paging func-
tion key to a line button on the D
term
s.
•
(1)
(2)
Y=00
My Line No. + + Key No.
F1278: All Zone Internal Paging
CM20
CM56
CM90
START
END
CM15
CM08
CM12
,