TRUNK GROUP BUSY DISPLAY
– 536 –
A2536-10
TRUNK GROUP BUSY DISPLAY
PROGRAMMING
HARDWARE REQUIRED
To provide the Trunk Group Busy Lamps on ATTCON:
ATTCON and DLC card
To provide the Trunk Group Busy Lamps externally:
DK card or MP card (built-in DK) and lamp indicator provided by customer
DESCRIPTION DATA
Assign the trunk group number to each
trunk.
Several trunks may be assigned to one
trunk group number.
•
(1)
(2)
Y=09
000-255: Trunk No.
01-62: Trunk Group No.
For providing the Trunk Group Busy
Lamps on ATTCON, assign the trunk
group number to required key.
NOTE 1: Max. 6 keys per ATTCON can be
assigned. Any six trunk group
number out of trunk group num-
ber 01-62 can be assigned.
NOTE 2: Key number 1-6 should not be
assigned to provide a Trunk
Group Busy Lamp.
•
(1)
(2)
Y=00
ATTCON No. (E000-E007) + + Key
No.
F12 XX
XX: 01-62: Trunk Group No. assigned
by CM30 Y=09
For providing external Trunk Group Busy
Lamp assign the Trunk Group number to
the required circuit number on the DK
card.
(1)
(2)
XX Y
XX : 00-31: DK Card No. assigned by
CM10 (E800-E831)
Y : 0-3: Circuit No.
313: MP built-in External Equipment In-
terface
11 XX
XX: 01-62: Trunk Group No. assigned
by CM30 Y=09
CM90
CM44
START
CM30
END
,