Page #195 background image
DELAY ANNOUNCEMENT-UCD
– 175 –
A2168-10
DELAY ANNOUNCEMENT-UCD
PROGRAMMING
DESCRIPTION DATA
Assign the Service Restriction Class A for
Digital Announcement Trunk Access
(Record/Replay/Delete) to the required
station.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
Allow Digital Announcement Trunk Access
in the Service Restriction Class A as-
signed by CM12 Y=02.
(1)
(2)
Y=33
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Specify the pattern of message sending to
each UCD group.
(1)
(2)
Y=A
X-XXXXXXXX: Pilot Station number of
the UCD Group
0 : To send periodically
1 : To send only once
Assign the Digital Announcement Trunk
card number to the required LEN.
NOTE: The Digital Announcement Trunk
card number must be assigned
to the first LEN (Level 0), the
third LEN (Level 2), the fifth LEN
(Level 4) and the seventh LEN
(Level 6) of LT slot.
(1)
(2)
000-763: LEN
EB002-EB127: Digital Announcement
Trunk Card No.
For PIM0/1: EB002-EB031
For PIM2/3: EB032-EB063
For PIM4/5: EB064-EB095
For PIM6/7: EB096-EB127
NOTE: EB000 and EB001 are dedi-
cated to built-in Digital An-
nouncement Trunk of the MP
card.
If the data for CM17 Y=A is “0”, set the in-
terval time for UCD Delay Announcement.
(1)
(2)
Y=0
47
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
CM17
START
CM12
CM10
A
CM41
CM15

Table of Contents

Other manuals for NEC NEAX 2000