DELAY ANNOUNCEMENT-UCD
– 176 –
A2168-10
HARDWARE REQUIRED
DAT card
× 1 per UCD Group is required
DESCRIPTION DATA
Specify the maximum UCD call waiting
time before answer or abandonment for
UCD Peg Count, and specify the waiting
time before UCD Delay Announcement.
•
(1)
(2)
Y=0
16
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
Assign the UCD Delay Announcement
function to required Digital Announcement
Trunk.
•
(1)
(2)
Y=00
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
Card No. EB002-EB127 as-
signed by CM10
0B0XX: UCD Delay Announcement
11XX: Second UCD delay announce-
ment
XX : 00-15: UCD Group No.
To record, replay and delete a message,
assign the Digital Announcement Trunk
access code, respectively.
•
(1)
(2)
Y=0-3 Number Plan Group 0-3
X-XXXX: Access Code
A100: Record
A101: Replay
A102: Delete
When transferring the call to a station or
Attendant after the 1st interval time of
UCD Delay Announcement, assign the
destination.
•
(1)
(2)
Y=17
00-63: Tenant No.
Destination
X-XXXXXXXX: Station No. or
E000: Attendant Console
Specify a diversion display on a D
term
or
Attendant Console when transferring a
UCD call.
(1)
(2)
357
0 : Available
1 : Not available
END
CM41
A
CM20
CM51
CM08
CM49