TOLL DENIAL/TOLL DIVERSION
– 523 –
A2523-10
TOLL DENIAL/TOLL DIVERSION
PROGRAMMING
In addition to the system data programming of TOLL RESTRICTION-3/6-DIGIT
page 527
,
do the following programming.
DESCRIPTION DATA
Provide the system with the Toll Diversion
or the Toll Denial.
(1)
(2)
119
0 : Toll Diversion (Routed to “ICPT”
key on ATTCON.)
1 : Toll Denial
(Routed to Reorder Tone)
Assign a Trunk Restriction Class to each
station.
(1)
(2)
Y=01
X-XXXXXXXX: Station No.
X Z: Trunk Restriction Class
X: 1-8: In Day Mode
Z: 1-8: In Night Mode
Specify the route access capability of each
Restriction Class.
See “RESTRICTION FROM OUTGOING
CALLS”.
page 414
(1)
(2)
Y=51-58
00-63: Trunk Route No.
0 : Restricted
1 : Allow
CM12
CM35
START
END
CM08