ATTENDANT SPEED CALLING-SYSTEM SET UP
– 41 –
A2032-10
ATTENDANT SPEED CALLING-SYSTEM SET UP
PROGRAMMING
DESCRIPTION DATA
Assign the password code for Attendant
Programming.
(1)
(2)
Y=30
1
XX-XX: Password (Max.8 digits)
X : 0-9, A(*), B(#)
If no data is set, the default setting is
NONE. In this case, the password is set to
“12345678”.
Assign the programming key for providing
Attendant Programming on ATTCON/
DESKCON.
(1)
(2)
Y=00
ATTCON No. (E000-E007) + + Key
No.
F6111
Assign the access code for providing At-
tendant Programming for ATTCON/
DESKCON, if required.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A156
CM90
CM20
START
END
CM60
,