DESCRIPTION DATA
Assign a secretary station serial number
to each Station Hunting group.
NOTE: A maximum of 31 stations can be
members of the Secretarial Hunt
group.
•
(1)
(2)
Y=2
X-XXXXXXXX: Pilot Station No. (Termi-
nal) /All Member Sta-
tion No. (Circular)
00-30: Secretary Station Serial No.
Assign a station number to each secretary
station serial number assigned by CM18
Y=2.
Specify the Hunting capability of each sec-
retary station.
Set up the order of Secretary Hunting.
Assign secretary station numbers, one by
one, in order of the desired Secretary
Hunting, as shown below.
1st Operation (1) Station A
(2) Station B
2nd Operation (1) Station B
(2) Station C
•
(1)
(2)
•
(1)
(2)
•
(1)
(2)
Y=0
00-30 Secretary Station Serial No.
X-XXXXXXXX: Secretary Station No.
Y=1
00-30 Secretary Station Serial No.
5: Hunting (As per CM19 Y=2)
7: No Hunting
Y=2
00-30: Secretary Station Serial No. (A)
00-30: Secretary Station Serial No. (B)
Allow or restrict the ability to set Station
Hunting-Secretarial for a station with Do
Not Disturb set.
(1)
(2)
240
0 : Allow
1 : Restricted
START
END
CM18
CM19