Loading...
NIGHT CONNECTION-FIXED
NIGHT CONNECTION-FLEXIBLE
– 358 –
A2356-10
NIGHT CONNECTION-FIXED
NIGHT CONNECTION-FLEXIBLE
PROGRAMMING
To provide Night Connection Stations:
DESCRIPTION DATA
Assign a Night Connection Station to each
incoming trunk.
(1)
(2)
Y=03
000-255: Trunk No.
04: Direct-In Termination
(1)
(2)
Y=05
000-255: Trunk No.
X-XXXXXXXX: Night Connection Sta-
tion No.
Assign the destination to which a call is
forwarded when the Night Connection Sta-
tion is busy/no answer.
(1)
(2)
Y=14 When Night Connection Station
is busy
000-255: Trunk No.
01 : To TAS
04 : To Attendant Console
06 : Automatic Camp-On
15 : Keep the call ringing until the sta-
tion becomes idle
(1)
(2)
Y=16 When Night Connection Station
is no answer
000-255: Trunk No.
01 : To Attendant Console
03 : To TAS
15 : Keep the call ringing until the sta-
tion answers
Specify the timing for a call forwarding
when the Connection Station is no answer.
NOTE: This timing is also applied to Call
Forwarding-Don’t Answer, Auto-
matic Change of Night Service
and Group Diversion.
(1)
(2)
Y=0
01
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
CM41
START
END
CM30