MEET-ME PAGING-ATTENDANT
MEET-ME PAGING-STATION
– 310 –
A2298-10
MEET-ME PAGING-ATTENDANT
MEET-ME PAGING-STATION
PROGRAMMING
DESCRIPTION DATA
Assign the Paging Trunk (COT card and
DK card) to the required LEN.
NOTE: The DK card number must be as-
signed to the first LEN (Level 0)
and third LEN (Level 2) of each
LT slot.
(1)
(2)
000-763: LEN
D000-D255: COT Card
E800-E831: DK Card
For PIM0/1 : E800-E807
For PIM2/3 : E808-E815
For PIM4/5 : E816-E823
For PIM6/7 : E824-E831
NOTE: Circuit No. 3 of E831 is used
for built-in External Equip-
ment Interface of the MP card
by setting CM44.
Assign the Service Restriction Class A for
Paging Access to the required stations.
(1)
(2)
Y=02
X-XXXXXXXX: My Line No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
Allow Paging Access in the Service Re-
striction Class A assigned by CM12 Y=02.
(1)
(2)
Y=08
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Assign the Paging function to the DK card
or external equipment interface on the MP
card.
(1)
(2)
XX Y
XX : 00-31: DK Card No. assigned by
CM10 (E800-E831)
Y : 0-3: Circuit No. of DK card
313: MP built-in External Equipment In-
terface
02XX: Speaker Paging Start
XX: 00-09: Speaker Paging Zone 0-9
assigned by CM30 Y=28
CM12
CM15
CM44
START
CM10
A