CONSULTATION HOLD-ALL CALLS
CONSULTATION HOLD-ALL CALLS-D
term
– 168 –
A2168-10
CONSULTATION HOLD-ALL CALLS
CONSULTATION HOLD-ALL CALLS-D
term
PROGRAMMING
HARDWARE REQUIRED
D
term
and DLC card if required
DESCRIPTION DATA
Select the ringing pattern on station calls
with a trunk line placed in Consultation
Hold.
(1)
(2)
137
0 : Change from Internal Ringing
(CM08>138) to External Ringing
(CM35 Y=33) when transferring a
call
1 : External Ringing (CM35 Y=33)
Assign the Service Restriction Class C to
each station.
(1)
(2)
Y=07
X-XXXXXXXX: Station No.
00-15 : Service Restriction Class C
Allow the Switch Hook Flash capability in
the Service Restriction Class C assigned
by CM12 Y=07.
(1)
(2)
Y=88, 89
Switch Hook Flash on Internal Call
Y=90, 91
Switch Hook Flash on External Call
00-15: Service Restriction Class C as-
signed by CM12 Y=07
1 : Available
(Special Dial Tone Connection)