RESTRICTION FROM OUTGOING CALLS
– 414 –
A2412-10
RESTRICTION FROM OUTGOING CALLS
PROGRAMMING
DESCRIPTION DATA
Assign the Trunk Restriction Class to each
station.
(1)
(2)
Y=01
X-XXXXXXXX: Station No.
X Z: Trunk Restriction Class
X: For Day Mode
Z: For Night Mode
1 : Unrestricted (RCA)
2 : Non-Restricted 1 (RCB)
3 : Non-Restricted 2 (RCC)
4 : Semi-Restricted 1 (RCD)
5 : Semi-Restricted 2 (RCE)
6 : Restricted 1 (RCF)
7 : Restricted 2 (RCG)
8 : Fully-Restricted (RCH)
Specify the outgoing call capability on
each Trunk Restriction Class (RCA-RCH)
assigned by CM12 Y=01 to each route.
(1)
(2)
Y=51 RCA
Y=52 RCB
Y=53 RCC
Y=54 RCD
Y=55 RCE
Y=56 RCF
Y=57 RCG
Y=58 RCH
00-63: Trunk Route No.
0 : Restricted
1 : Allow
Specify the Outgoing Call transfer to a re-
stricted station.
(1)
(2)
021
0 : Restricted
1 : Allow
START
END
CM12
CM35
CM08

Table of Contents