OFF-HOOK ALARM
– 364 –
A2356-10
OFF-HOOK ALARM
PROGRAMMING
DESCRIPTION DATA
Provide Off-Hook Alarm for the required
stations.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
0: To provide
Assign the destination for Off-Hook Alarm
to a station or Attendant Console.
(1)
(2)
Y=12
00-63: Tenant No.
X-XXXXXXXX: Station No.
E000: Attendant Console
If Attendant Console is designated as the
destination of Off-Hook Alarm by CM51
Y=12, assign Off-Hook Alarm to any ICI
keys.
(1)
(2)
Y=00
ATTCON No. (E000-E007) + + Key
No.
F6066: Off Hook Alarm
Specify the timing for Off-Hook Alarm.
(1)
(2)
Y=0
22
01-08: 4 sec.-32 sec.
(4 sec. increments)
If no data is set, the default setting is 28-32
sec.
Assign the Service Restriction Class C for
an Off-Hook Alarm Call to busy destina-
tion.
(1)
(2)
Y=07
X-XXXXXXXX: Station No. of destina-
tion
00-15 : Service Restriction Class C
Allow the Off-Hook Alarm call in the Ser-
vice Restriction Class C assigned by
CM12 Y=07.
CM15
CM15
Y=97 Y=98 SERVICE
0 0 UCD/Call Waiting NOTE
0 1 UCD
1 0 Call Waiting
1 1 Hunting
NOTE: Call Waiting is automatically se-
lected, if UCD is not provided to
the system.
(1)
(2)
Y=97
Y=98
00-15: Service Restriction Class C as-
signed by CM12 Y=07
See left column.
CM51
CM90
CM41
START
END
CM13
CM12
CM15
,