NAME DISPLAY-D
term
– 357 –
A2356-10
NOTE 1: The maximum number of stations that can be provided with the user’s name display is
512. The maximum number of characters per name is eight, including spaces.
NOTE 2: User’s name can be assigned to Single Line Telephone.
NOTE 3: The trunk name display is provided on a trunk route basis. The maximum amount of
characters in the trunk name display is four. And the maximum number of trunk routes
assignable is 16.
NOTE 4: There are two ways to change a name that is currently programmed. By overwriting
with a new name, or by inserting a blank space as the first character will cancel the ex-
isting name.
HARDWARE REQUIRED
D
term
and DLC card
DESCRIPTION DATA
Enter the desired station user’s name to
each station number by CM77 Y=0 or
CM77 Y=1.
(1)
(2)
Y=0 By Character Code
X-XXXXXXXX: Station No.
Character Code 20-7F: Max. 32 digits
See APPENDIX B: CHARACTER
CODE TABLE.
(1)
(2)
Y=1 By Character
X-XXXXXXXX: Station No.
A-Z, 0-9: Character
Max. 16 characters
Assign the desired trunk name to each
trunk route by CM77 Y=2 or CM77 Y=3.
(1)
(2)
Y=2 By Character Code
00-14, 16-63: Trunk Name No. as-
signed by CM35 Y=03.
Character Code 20-7F: Max. 8 digits
See APPENDIX B: CHARACTER
CODE TABLE.
(1)
(2)
Y=3 By Character
00-14, 16-63: Trunk Name No. as-
signed by CM35 Y=03.
A-Z, 0-9: Character Code
Max. 4 characters
END