EasyManua.ls Logo

NEC NEAX 2000 - Page 104

NEC NEAX 2000
1200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CALL FORWARDING-ALL CALLS
CALL FORWARDING-ALL CALLS-D
term
CALL FORWARDING-ALL CALLS-OUTSIDE
– 84 –
A2076-10
HARDWARE REQUIRED
D
term
and DLC card if required
DESCRIPTION DATA
(1)
(2)
Y=0
Incoming Trunk Route No. + Outgoing
Trunk Route No. assigned by CM35
Y=05
0: Allow
Specify the setting method for Call For-
warding-All Calls-Outside.
(1)
(2)
222
0 : The feature is set when the station
goes on hook/when receiving Ser-
vice Set Tone (ORT time out)
1 : The feature is set when receiving
Service Set Tone (ORT time out)
Assign whether or not an extension can
set Call Forwarding-All Calls-Outside by
entering only a trunk access code.
(1)
(2)
386
0 : Restrict
1 : Allow
Assign whether or not the system should
check the trunk restriction class of the for-
warded station during a Call Forwarding-
All Calls-Outside.
(1)
(2)
387
0 : Call forwarding All Calls-Outside
follows setting station class
1 : No check
Provide Call Forwarding feature with each
tenant as per incoming call type.
(1)
(2)
Y=23 Internal Call or ATT assisted Call
Y=24 C.O. Incoming Call
Y=25 Tie Line Incoming Call
00-63: Tenant No.
1 : Call Forwarding
Select the Dial Tone on setting Call For-
warding-All Calls.
(1)
(2)
Y=2
13: Dial Tone on Setting Call Forward-
ing-All Calls
0 : Special Tone
1 : Dial Tone
CM48
END
CM36
A
CM08
CM65
INITIAL

Table of Contents