CALL WAITING-TERMINATING
– 146 –
A2131-10
To provide an outside party on DID call with the Call Waiting feature:
DESCRIPTION DATA
Specify the Camp-On (Call Waiting) Tone
sent to a busy station.
(1)
(2)
367
For Australia/Other Countries:
0 : Every 4 sec.
1 : Only once
For New Zealand:
0 : Only once
1 : Every 2 min.
Assign the Call Waiting for DID call to the
Trunk Route.
(1)
(2)
Y=59
00-63: Trunk Route No.
0 : To provide
1 : Not provided
Specify the number of times for Call Wait-
ing tone.
NOTE: This data is effective when the
2nd data of CM08>367: 0.
(1)
(2)
18
01-99: Number of Times
If no data is set, the default setting is no lim-
itation.
Allow the Call Waiting for DID call per sta-
tion number.
NOTE: This data is effective when the
2nd data of CM35 Y=18: 0.
(1)
(2)
Y=10
000-999: Number Conversion Block
No. assigned by CM76 Y=00
1 : Allow