– 211 –
A2195-10
DIRECT DIGITAL INTERFACE (DDI)
PROGRAMMING
24-DTI Assignment
DESCRIPTION DATA
Specify the various timing, if required.
(1)
(2)
Y=3
00: Release Signal Detect Timing
01-15: 64 ms.-960 ms.
(64 ms. increments)
If no data is set, the default setting is 128
ms.
(1)
(2)
Y=3
01: Answer Signal Detect Timing
01-15: 32 ms.-480 ms.
(32 ms. increments)
If no data is set, the default setting is 128
ms.
(1)
(2)
Y=3
02: Wink Signal width
01-15: 64 ms.-512 ms.
(32 ms. increments)
If no data is set, the default setting is 32 ms.
(1)
(2)
Y=3
03: Wink/Delay Detection Timeout
01-15: 1 sec.-15 sec.
(1 sec. increments)
If no data is set, the default setting is 7 sec.
Assign an access code for the DTI trunk
route.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
100-163: Trunk Route No. 00-63
NOTE: The Least Cost Routing or Route Advance feature is available for call origination
via the DTI.
Refer to the following feature programming.
LEAST COST ROUTING-3/6 DIGIT
page 286
LEAST COST ROUTING-TIME OF DAY ROUTING
page 298
ROUTE ADVANCE
page 420
CM20