DIRECT OUTWARD DIALLING (DOD)
– 228 –
A2222-10
DESCRIPTION DATA
(1)
(2)
Y=04 Answer Signal Condition
00-63: Trunk Route No.
0 : Answer Signal by Meter Pulse
1 : Answer Signal by Polarity Reversal
7 : No Answer Signal
In case of No Answer Signal, system recog-
nizes the answer in timing set by CM41
Y=0>03.
(1)
(2)
Y=05 Release Signal Condition
00-63: Trunk Route No.
0 : No Release Signal from C.O.
1 : Release Signal from C.O.
(1)
(2)
Y=08 Dial Pulse Sending
00-63: Trunk Route No.
3 : To send
(1)
(2)
Y=09 Incoming Connection Signalling
00-63: Trunk Route No.
01 : Ring Down (Ground Start)
15 : Ring Down (Loop Start)
(1)
(2)
Y=39 Trunk Release by Reverse Signal
from C.O.
00-63: Trunk Route No.
1 : To release
According to the characteristics of each
C.O. line, assign the data for DP/DTMF
Sender to each route.
For details of the command, refer to Com-
mand Manual.
NOTE: For Resident System Program,
refer to the Command Manual.
Y=20 Sender Start Condition
Y=21 Sender Prepause Timing
Y=23 DP Inter-Digital Pause
Y=24 DTMF Inter-Digital Pause
Y=25 DP Make Ratio
Y=26 DTMF Signal Width
Y=45 DP Sender Release Timing
Y=46 DTMF Sender Release Timing
CM35
A
B

Table of Contents