DISTINCTIVE RINGING
– 235 –
A2234-10
DESCRIPTION DATA
Specify ringing signal patterns for incom-
ing internal/external call, if required.
(1)
(2)
392
-Pattern 1
0 : 2 sec. ON-4 sec. OFF
1 : 0.4 sec. ON-0.2 sec. OFF
-0.4 sec. ON-2 sec. OFF
-Pattern 2
0 : 0.5 sec. ON-0.5 sec. OFF
-0.5 sec. ON-1.5 sec. OFF
(D
term
)
0.4 sec. ON-0.2 sec. OFF
-0.4 sec. ON-2 sec. OFF
(Single Line Tel)
1 : 0.2 sec. ON-0.2 sec. OFF
-0.2 sec. ON-0.2 sec. OFF
-0.2 sec. ON-2 sec. OFF
Specify interval of ringing signal to station
on incoming calls, if required.
NOTE: For incoming calls to a Trunk
Line Appearance key on D
term
s,
the special ringing, 0.2 sec. ON,
0.2 sec. OFF will be applied.
•
(1)
(2)
Y=33
00-63: Trunk Route No.
0 : 0.4 sec. ON-0.2 sec. OFF,
0.4 sec. ON-2 sec. OFF
NOTE
1 : 0.4 sec. ON-0.2 sec. OFF,
0.4 sec. ON-2 sec. OFF
2 : 1 sec. ON-2 sec. OFF
3 : As per CM08>392-Pattern 1
CM08
END
CM35
INITIAL
A