LEAST COST ROUTING-TIME OF DAY ROUTING
– 299 –
A2298-10
DESCRIPTION DATA
Assign the Route Pattern number to the
required time of day for the Time Pattern
number assigned by CM8A Y=3000-3003.
To define the following Time Pattern:
(1)
(2)
Y=2000-2007
Time Pattern No. 0-7
HH MM (Time)
HH : 00-23: Hours
MM: 00/30 Minutes
0000-0255: Route Pattern No. 000-255
If Tenant Pattern is required, set 1000-1015
(Tenant Pattern No. 00-15).
If the Tenant Pattern number is assigned
by CM8A Y=2000-2007, assign the Route
Pattern number to the required Tenant
number for the Tenant Pattern number.
(1)
(2)
Y=1000-1015
Tenant Pattern No. 00-15
00-63: Tenant No. 00-63
0000-0255: Route Pattern No. 000-255
END
CM8A
A
Route
Pattern 000
Route
Pattern 000
Route
Pattern 001
0:00 8:00 20:00 23:30
Y TIME (1) ROUTE PATTERN (2)
2000
(Time Pattern No. 0)
2000
(Time Pattern No. 0)
0000
0030
0100
0130
0200
0730
2000
2030
2330
0800
0830
1930
0000
(Route Pattern 000)
0001
(Route Pattern 001)
12:00 PM-8:00 AM
8:00 PM-12:00 PM
8:00 PM-8:00 PM