AC METERING COT
– 12 –
A2008-10
HARDWARE REQUIRED
SMDR or D
term
TIMS.
For DTI Metering, 30DTC is required.
DESCRIPTION DATA
Assign the Answer Signal Detect Timing
on the DTI trunks.
(1)
(2)
Y=3
01
01-15: 32 ms.-480 ms.
(32 ms. increments)
If no data is set, the default setting is
128 ms.
Assign the Process for detection of Meter-
ing Signal.
(1)
(2)
Y=3
14
00: Process 1 (for Australia)
01: Process 2 (for Argentina)
Initial Data: NONE (Process 1)
Assign the Metering Signal Detect Timing
on the DTI trunks.
(1)
(2)
Y=3
15
01-15: 32 ms.-320 ms.
(32 ms. increments)
If no data is set, the default setting is
160 ms.
END