– 328 –
A2325-10
MESSAGE CENTER INTERFACE (MCI)
PROGRAMMING
MCI Programming
MCI Programming
After AP Initialization, do the following programming.
Call Forwarding to the VMS stations, and UCD Group/Station Hunting Group set to the VMS sta-
tions are required. For these feature programming, refer to each feature in this manual.
DESCRIPTION DATA
Provide the VMS with MCI. (1)
(2)
443
0: VMS with MCI
Specify MSG display on the D
term
. (1)
(2)
025
0 : MSG (only)
1 : MSG X (X: Number of message)
Specify Message Waiting control from
VMS with MCI to all stations.
NOTE: MW lamp control is only avail-
able to the stations in the oppo-
site PBX connected with CCIS
via MCI. Station dialing MW ac-
cess codes are not allowed over
CCIS.
(1)
(2)
444
0 : Available
1 : Not available
Specify whether Message Waiting from
the VMS is provided for the called station
when a forwarded call is terminated to the
VMS via CCIS.
(1)
(2)
376
0 : To provide
1 : Not provided
Provide Message Waiting for a station with
MW lamp.
(1)
(2)
Y=03
X-XXXXXXXX: Station No.
0: To provide
Provide VMS service for a station port
interface with the VMS (VMS station).
(1)
(2)
Y=10
X-XXXXXXXX: Station No.
(VMS station)
0: To provide
Provide Momentary Open for a station
port interface with the VMS (VMS station),
as required.
(1)
(2)
Y=22
X-XXXXXXXX: Station No.
(VMS station)
0: To provide
CM13
START
CM08
A

Table of Contents