PAD LOCK
– 373 –
A2369-10
(2) With MP card
DESCRIPTION DATA
Designate the MP card for Authorization
Code.
(1)
(2)
216: Designation of Processor for Au-
thorization Code
0: MP card
Specify the Service Set Tone after dialing
the access code for Authorization Code.
(1)
(2)
362: Service Set Tone after dialing the
access code
1 : Service Set Tone
Set the data for 281 to 1. (Maid ID Code is
not used.)
(1)
(2)
281
1 : Not available
Assign the Service Restriction Class A al-
lowed for Authorization Code feature.
•
(1)
(2)
Y=31 Authorization Code
00-15: Service Restriction Class A
1 : Allow
Assign allowed class and restricted class
for Maid Status feature in Service Restric-
tion Class B.
•
(1)
(2)
Y=75 Maid Status
00-15: Service Restriction Class B
0 : Restricted
1 : Allow
To the station that uses Pad Lock feature,
assign the Service Restriction Class A al-
lowed for Authorization Code feature.
Moreover, to all the station, assign the Ser-
vice Restriction Class B restricted for Maid
Status feature.
•
(1)
(2)
Y=02
X-XXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
ZZ: 00-15 : Service Restriction Class
B
Assign the access code for Authorization
Code.
•
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A086: Authorization Code
CM15
CM12
CM20
START
CM08
A