SPEED CALLING-STATION
– 447 –
A2437-10
DESCRIPTION DATA
Assign the programmable pause for
Speed Calling-Station.
(1)
(2)
Y=0
38
00-07: 1.5 sec.-12 sec.
(1.5 sec. increments)
If no data is set, the default setting is 1.5
sec.
Allocate the memory area for Speed Call-
ing-Station to each station.
(1)
(2)
X-XXXXXXXX: Station No.
W XX Y ZZ
W : 0-3 (Basic), 4-9 (Option):
1000-Slot Memory Block No.
XX: 00-99: Memory Start Block No.
(10-Slot Memory Block)
Y : Facility for programming the dialed
number from the station
0/1Effective/Ineffective
ZZ: 01-10: Number of 10-Slot Memory
Blocks
NOTE 1: 1000-Slot Memory Block number 4-9 (6000 Memory Parcels) can be used when
the Expansion Memory card (PZ-M537) is mounted on the MP card.
For using this memory area, there are several conditions as mensioned below:
This memory area cannot be used for Speed Calling with Speed Calling keys
provided by CM90: F11XX on a D
term
, and cannot also be used for Speed Call-
ing-System.
When exchanging the Expansion Memory card for another, data setting for this
memory area must be reentered.
The Office Data in this memory area can be saved and loaded by MAT opera-
tions.
CM41