EasyManua.ls Logo

NEC NEAX 2000 - Page 554

NEC NEAX 2000
1200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TRUNK ANSWER FROM ANY STATION (TAS)
– 534 –
A2523-10
To provide the External TAS Indicator via DK card:
DESCRIPTION DATA
Assign the card number of DK to required
LEN.
NOTE: The DK card number must be
assigned to the first LEN (Level
0) and the third LEN (Level 2) of
each LT slot.
(1)
(2)
000-763: LEN
E800-E831: DK Card No.
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
Assign the TAS Group number assigned
by CM30 Y=17 to circuit number of DK
card.
NOTE: MP built-in External Equipment
Interface is not available for Ex-
ternal TAS Indicator Connection.
(1)
(2)
XX Y
XX: 00-31: DK Card No. assigned by
CM10 (E800-E831)
Y : 0-3: Circuit No.
13XX
XX: 00-63: TAS Group No. 00-63
assigned by CM30 Y=17
Specify the indication pattern on External
TAS Indicator.
(1)
(2)
00
01: 30 IPM (1 sec. ON/OFF)
02: 60 IPM (0.5 sec. ON/OFF)
03: 120 IPM (0.25 sec. ON/OFF)
07: Steady on
NONE : 120 IPM (0.25 sec. ON/OFF)
CM44
CM59
START
END
CM10

Table of Contents

Other manuals for NEC NEAX 2000

Related product manuals