ATTENDANT DELAY ANNOUNCEMENT
– 36 –
A2032-10
HARDWARE REQUIRED
DAT card or MP card (built-in DAT)
DESCRIPTION DATA
To record, replay and delete a message,
assign the Digital Announcement Trunk
access cords, respectively.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A100: Record
A101: Replay
A102: Delete
Specify the unanswered timing of mes-
sage replay.
(1)
(2)
Y=0
16
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
Specify the interval time of message re-
play.
(1)
(2)
Y=0
47
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
CM41
END