XPS Unified Programmer’s Manual
Prototype
int PositionerCompensationPhaseCorrectionFiltersSet(
int SocketID,
char * FullPositionerName,
double PhaseCorrectionFn1,
double PhaseCorrectionFd1,
double PhaseCorrectionGain1,
double PhaseCorrectionFn2,
double PhaseCorrectionFd2,
double PhaseCorrectionGain2
)
Input parameters
SocketID int Socket identifier gets by the
“TCP_ConnectToServer” function.
FullPositionerName char * Positioner name.
PhaseCorrectionFn1 double Numerator frequency (Hertz) for phase
correction filter #1.
PhaseCorrectionFd1 double Denominator frequency (Hertz) for phase
correction filter #1.
PhaseCorrectionGain1 double Gain for phase correction filter #1.
PhaseCorrectionFn2 double Numerator frequency (Hertz) for phase
correction filter #2.
PhaseCorrectionFd2 double Denominator frequency (Hertz) for phase
correction filter #2.
PhaseCorrectionGain2 double Gain for phase correction filter #2.
Output parameters
None.
Return (In addition to the results of “Input Tests Common to all XPS
Functions”)
0: No error.
-8: Wrong object type for this command.
-17: Parameter out of range or incorrect.
EDH0373En1023 01/18 288

Table of Contents

Other manuals for Newport XPS-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Newport XPS-D and is the answer not in the manual?

Newport XPS-D Specifications

General IconGeneral
BrandNewport
ModelXPS-D
CategoryController
LanguageEnglish

Related product manuals