XPS Unified Programmer’s Manual
7.2.2.52 ZygoReadLong
Name
ZygoReadLongRead a long register from a ZMI Measuring board.
Input tests
- Refer to section 7.1: “Input Tests Common to all XPS Functions”.
Description
This function reads a LONG register (max 32-bits) from a ZMI Measuring board.
Example
Read Control Register 1 on Axis 1:
ZygoReadLong (AXIS1, A)
ZMI Measuring board Response:
#H70
Prototype
int ZygoReadLong(
int SocketID,
char * AxisNum,
char * Register,
char * Response
)
Input parameters
SocketID int Socket identifier gets by the
“TCP_ConnectToServer” function.
AxisNum char * “AXIS1” or “AXIS2”.
Register char * Register value in hexadecimal.
Output parameters
Response char * Response returned by the ZMI Measuring board.
Return (In addition to the results of “Input Tests Common to all XPS
Functions”)
0: No error.
-2: TCP timeout.
-1000: Zygo command execution failed.
-1001: The controller is not connected to Zygo TCP server. Run
ZygoStartInterferometer API.
Zygo errors: Refer to section 8.9: “Error List”.
EDH0373En1023 01/18 650

Table of Contents

Other manuals for Newport XPS-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Newport XPS-D and is the answer not in the manual?

Newport XPS-D Specifications

General IconGeneral
BrandNewport
ModelXPS-D
CategoryController
LanguageEnglish

Related product manuals