XPS Unified Programmer’s Manual
Return (In addition to the results of “Input Tests Common to all XPS
Functions”)
0: No error.
-17: Parameter out of range or incorrect.
-22: Not allowed action.
-25: Following Error.
-26: Kill command or Emergency signal: check each positioners and each
slave positioners, check that motion does not exceed software limits
when combined with mapping and other features.
-27: Move Aborted.
-28: Home search timeout.
-33: Motion done timeout.
-35: Position is outside of travel limits.
-44: Slave error disabling master.
-49: Inconsistent mechanical zero during home search.
-50: Motor initialization error. Check InitializationAccelerationLevel,
ScalingAcceleration, MaximumJerkTime, EncoderResolution or
EncoderScalePitch.
-113: Both ends of run activated.
-120: Warning following error during move with position compare enabled.
-200: Invalid socket.
-205: Not enable in your configuration.
EDH0373En1023 01/18 610